Diet Fast Forward – The New User Manual

Diet Fast Forward – The New User Manual For Download

 

 

INSTALL YOUR APP – DIET FAST FORWARD FREE APP FOR ANDROID

INSTALL YOUR APP – DIET FAST FORWARD FREE APP FOR iOS

 

PLEASE NOTE THAT THIS IS AN IMAGE OF THE NORMALLY POSITIONED SENSOR:

 

DIET FAST FORWARD WELCOME LETTER DOWNLOAD HERE

DietFastForward.com

 

Dear Customer, 

Welcome to DIet Fast Forward.com and thank you for your purchase and trust. 

We would like to welcome you to the DietFastForward community and hope that you will have a great experience with us and our product.

TO SECURE THE TOP QUALITY OF OUR PRODUCT FOR YOUR CONVENIENT EXPERIENCE, WE WOULD LIKE TO CONFIRM THAT THE PRODUCTION FACILITY HOLDS THE FOLLOWING CERTIFICATES CONCERNING THE PRODUCTION PROCESS AND THE DIET FAST FORWARD PRODUCT:

  1. Certificate of Registration with the U.S. Food and Drug Administration FY 2020, to Title 21, 807 et sequence. United States Code of Federal Regulations Establishment Number 10061354 Product Code DJZ
  1. ISO Quality Management System GB/T 19001-2016/ISO 9001:2015 Standard
  1. RoSH Marking Certificate of Conformity – Certificate number TB 190622120 Test Standards 2011/65 EU& 2015/863/EU; IEC 62321: 2013/2015/2017 with the council of RoSH Directive 2015/863/EU According to EN50581
  1. CE Marking Certificate of Conformity – Certificate Number TB 190622119 Test Standards EN 61000-6-3: 2007+A1: 2011; EN 61000-6-1: 2017 Council Directive 2014/30/ EU Test report number TB-EMC166884

 

In order to meet your expectations, we would like to point out some common notes.

NOTES: When it comes to measurements, especially self measurements and more specifically breath meter measurements it is very important to keep measuring standards which include measuring at specific times, maintain a similar state of the body, and constant blowing technique.

In that sense, our recommendations are to perform your measurements in the morning approximately at the same time. (For example, 5 to 10 minutes after you weak up.) 

Additionally, your measurements should performed on an empty stomach, and “unaffected body”. (For example, before exercise or other activities that affect your breathing.)

Finally, you should develop blowing techniques in order to get consistent results. (For example, as the acetone levels in the lungs vary depending on the depth of the breath when you exhale while performing your measurements as well as the acetone levels are dropping every time you exhale, it is important to perform the measurements with the same blow strength as breathing.)

Also, as you are measuring we recommend performing your measurements at list 3 times in a row to find an average of the measurements for the most reliable result. You can track those levels and compare them daily. For further INSTRUCTIONS and UPDATES and LINKS for the APP, please scan the QR code below or follow the link: https://ketofastforward.com/intructions 

SCAN TO VISIT: https://ketofastforward.com/intructions

 

If you have any further questions or are facing any issues, please get in touch with our SUPPORT at https://ketofastforward.com/support

SCAN TO VISIT: https://ketofastforward.com/support

 

All the best, 

 

DietFastForward Support Team

US: +19292141820

EU: +46766920988

 

 

 

Diet Fast Forward – The New User Manual – Ketone Meter

1. Breath inhaler tube

2. Power button ON / OFF

3. LCD display

4. Battery compartment (AAA 1.5V x 2 – NOT included)

Reference

States of nutritional ketosis is defined as 0.50-3.00 mmo/L

Users reported that in fasted state they went as high as 0 .50 mmol/L

CAUTIONS

The following situations could affect your result. Use the device after the displayed times below.

Brushing teeth, Mouthwash                                                     Consuming candy or Gum

(Within 30 minutes)                                                                      (Within 30 minutes)

Smoking                                                                                       Food

(Within 30 minutes)                                                                      (Within 30 minutes)

Drinking , or  the Morning after                                            Coffee, tea, or beverage other than water

(Within 24 hours)                                                                      (Within 30 minutes)

To be in nutritional ketosis state, you should be getting consistent results for at least two weeks.

Features

Ketones monitor

Quick response and resume

5x mouthpiece

Auto Power off

Use 2x AAA alkaline batteries (NOT included)

Installing the battery

Slide open the battery compartment lid from the back of the unit

2. Insert two AAA (um-4) alkaline batteries with correct polarity as indicated

3. Replace – close the battery compartment lid back

How to use the keto monitor

warm up

1. Press and hold the power button for a second. The Keto monitor LCD will turn on with one beep sound.

2. The “warm up” symbol is displayed, and the 15 to 00 countdown have started which indicates that the meter is in warm-up mode.

Note

There is a large number of gas and impurity absorbed on the surface of ketone monitor when the keto monitor for the first time is taken out of the packaging, or after a long time of no use. In those situations, it needs more time for cleaning and warming up the sensor. You should repress the power button and retry several times if possible.

Additional information

Press the power button to start the device. The device will warm up and start counting down for 15 seconds.

After the warm up, comes the blow countdown from 10 to 00 seconds. During the blow countdown, blow normally into the device.

Read the results on the LCD display. If you’re in Ketosis state, you should be getting 0.10 – 7.00 readings displayed.

 Replicate the test every morning in a fasted state for best accuracy.

Auto power OFF.

After the result are displayed for about 10 seconds, the“OFF” symbol will appear for 2-3 seconds and the keto monitor will be turned off automatically.

Backlight

When the keto monitor is turned on, the LCD backlight will light until the keto monitor is auto powered off.

Replacing battery

The LCD flickering indicates low power of the batteries, please replace two AAA alkaline batteries

How to use it correctly:

1.  For most accurate results take measurement at fasted state in the morning.

2. Do not consume alcohol before usage.

3. Don’ t be dehydrated.

4. Measure the last few seconds of your exhaled breath. The first few seconds are mostly room air.

Once the full Blow period has completed, the device will report the necessary reading by showing “Result”on the screen.

Readings of 0.00 signify the person is still not in ketosis state.

Readings of 0.20 – 0.50 signify the person is in a light state of ketosis (the process of fats being used by the body as the main source of energy has begun).

Readings of 0.50 – 3.00 signify the person is in full state of ketosis, which is the optimal ketone zone (the process of fats being used by the body as the main source of energy).

Readings over 3.00 signify the person is in starvation ketosis.

Readings over 5.00 signify the person is in too much ketosis and need medical care.

Readings over 7.00 signify the person is in keto acidosis.

 

ATTENTION: This product is not intended for ages under 18. There is a risk of swallowing of the plastic inhaler tube, so keep the product out of reach of risk groups especially small children. The use of this product is on your own risk.
Easy share:
0
Diet Fast Forward 2.0 SYSTEM
×